ADDITIVE SOCOSURF TCSADD1 20L/5,3GAL PLAST PAIL

ERP Code
P61809-20L-P-1
More Information
Description

Sold by: 20L can

Additive for the upgrade and maintenance of SOCOSURF TCS / SOCOSURF PACS baths.

Baths should be monitored to ensure the best performance. The bath monitoring process is detailed in the control test document.

Products required for bath maintenance:

  • SOCOSURF TCS
  • SOCOSURF TCSADD1
  • SOCOSURF PACS
  • 35% Technical Grade Hydrogen Peroxide
  • 5% Ammonia Solution
  • 5% Sulphuric Acid Solution
  • 5% Nitric Acid Solution
More Information
Approvals
  • ALSTOM
  • BOMBARDIER
  • COLLINS AEROSPACE
  • DASSAULT AVIATION
  • DEUTSCHE AIRCRAFT
  • Daher
  • GE
  • LEONARDO AIRCRAFT
  • LEONARDO HELICOPTERS
  • LIEBHERR AEROSPACE
  • LOCKHEED MARTIN
  • THALES GLOBAL SERVICES
More Information
SKU (GTIN) 3665792002730
Format Liquid
Usage unit Liter
Usage unit quantity 20
ERP Code P61809-20L-P-1
Regulatory constraints Each customer is responsible for verifying the regulatory constraints incumbent on him for import and transport

Surface Treatment Engineering FAQ

How does SOCOSURF TCS/PACS compare to Cr(VI) treatments?

SOCOSURF TCS/PACS offer comparable corrosion resistance to Cr(VI), meeting 168 hours of salt spray testing (SST) on aluminum alloys like 2024-T3, with compliance to MIL-DTL-81706 standards.

What are the pH, temperature, and concentration requirements?

SOCOSURF TCS operates at pH 3.8-4.0, 35-45°C, with 31-41% concentration. SOCOSURF PACS operates at pH 4.2-5.3, 15-30°C, with 8-12% concentration.

Does SOCOSURF PACS enhance corrosion resistance?

Yes, SOCOSURF PACS enhances corrosion resistance by extending salt spray resistance up to 168 hours on sensitive aluminum alloys.

What maintenance is required for the SOCOSURF TCS/PACS baths?

Regular maintenance includes monitoring pH, concentration, and peroxide levels. Filtration and periodic cleaning of tanks are also necessary. Bath chemistry should be adjusted according to analysis results.

Purchasing / Procurement FAQ

What are the lead times and availability for SOCOSURF TCS/PACS?

Lead times depend on the region, but SOCOSURF products are globally available with support from local distributors.

How do I optimize the reordering process for SOCOSURF products?

Use historical usage data to predict reordering needs, ensure consistent supplier communication, and keep a safety stock based on production demands.

HSE FAQ

Are SOCOSURF TCS and PACS REACh compliant?

Yes, both SOCOSURF TCS and PACS are REACh compliant, free from Cr(VI) and other substances of very high concern (SVHC).

Maintenance & Operations FAQ

What are the bath temperature requirements for SOCOSURF TCS/PACS?

SOCOSURF TCS requires a bath temperature of 35-45°C, while SOCOSURF PACS requires 15-30°C for optimal performance.

How do I prevent hydrogen peroxide degradation in the PACS bath?

To prevent hydrogen peroxide degradation, keep the tank covered when not in use, reduce tank temperature to avoid exceeding 30°C, and minimize agitation.